The number of sanitary facilities provided for the population and occupancy of the building to be served, shall be adequate, if in accordance with the tables below.

CALCULATION OF THE NUMBER OF SANITARY FACILITIES

Occupancy

Population

Facilities

Entertainment and public assembly

Staff

Table 6

Public

1 wc + 1 whb (M)

1 wc + 1 whb (F)

Theatrical and indoor sports

Staff

Table 6

Public

Table 7 (O/Peak + Peak)

Participants

Table 8

Places of Instruction

N/A

Table 6

Places of Worship

Staff

Table 6

Public

1 wc + 1 whb (M)

1 wc + 1 whb (F)

Outdoor Sports

Public

Table 7 (Peak)

Table 7 (O/Peak)

Participants

Table 8

Commercial Service (All Risks)

Staff

Table 6

Public

1 wc + 1 whb

Exibition Hall and Museums

Staff

Table 6

Public

1 wc + 1 whb (M)

1 wc + 1 whb (F)

Industrial (All Risks)

Staff

Table 6

Public

No Seperate Div

Large Shop

Staff

Table 6

Public

1 wc + 1 whb (M)

1 wc + 1 whb (F)

Small Shop and Wholesalers Store

Staff

Table 6

Public

1 wc + 1 whb

Offices

Staff

Table 6

Public

1 wc + 1 whb (M)

1 wc + 1 whb (F)

Hotels

Staff

Table 6

Public

1 wc + 1 whb (M)

1 wc + 1 whb (F)

Residents

Table 5

Dormitories

N/A

Table 5

Residences and Dwellings

N/A

1 wc + 1 whb + 1 Bath or Shower

Storage (All Risks)

Staff

Table 6

Educational Institutions

Staff

Table 6

Students

Table 7

Place of Detention, Hospital and other Institutions

N/A

Number to be provided, depends on type and design. Table 5 may be used as a guideline

Exemptions

1.      In any building where facilities in accordance with Table 6 are available to both staff members and the public, no seperate facilities shall be required for the public.

2.      No seperate facilities for the public shall be required within any shop having a floor area less than 50 sqm. In any group of shops under one ownership or complex on a single site -

o        Facilities for staff members may be situated at convenient locations and not necessarily in any particular shop or shops.

o        Facilities for the public may be situated at convenient locations and not necessarily in any particular shop or shops.

o        Facilities for staff members may be combined with those for the public.

3.      If staff members are exposed to high risk substances, dirt, dust, oil, soot, grease or similar substances that makes showers necessary, at least 1 shower per 15 persons shall be provided separately for each sex, and those showers shall be located near to, or have direct access to change rooms.

TABLE 5

For a population of up to-

Number of sanitary facilities to be provided relative to the population

Males

Females

wc

ur

whb

baths

wc

whb

baths

8

1

1

1

1

2

1

1

20

1

2

2

2

3

2

2

40

2

3

3

3

4

3

3

60

3

4

4

4

6

4

4

80

4

6

5

5

9

5

5

100

4

8

6

6

12

6

6

120

5

9

6

6

14

7

7

140

5

10

7

7

15

8

8

180

5

11

8

8

16

8

8

 

For a population in excess of 180 add 1 wc for every 50 persons

For a population in excess of 180 add 1 urinal for every 40 persons

For a population in excess of 180 add 1 whb and 1 bath for every 50 persons

For a population in excess of 180 add 1 wc, 1 whb and 1 bath for every 60 persons

 

TABLE 6

For a population of up to-

Number of sanitary facilities to be provided relative to the population

Males

Females

wc

ur

whb

wc

whb

15

1

1

1

2

1

30

1

2

2

3

2

60

2

3

3

5

3

90

3

5

4

7

4

120

3

6

5

9

5

   

For a population in excess of 120 add 1 wc, 1 urinal and 1 whb for every 100 persons

For a population in excess of 120 add 1 wc for every 50 persons

For a population in excess of 120 add 1 whb for every 100 persons

 

TABLE 7

For a population of up to-

Number of sanitary facilities to be provided relative to the population

Facilities subject to peak demand

Males

Females

wc

ur

whb

wc

whb

50

1

1

1

2

1

100

1

2

1

3

2

150

1

3

1

5

3

250

2

4

2

7

4

500

3

7

3

12

6

1000

3

12

4

16

7

1500

4

15

5

20

8

 

For a population in excess of 1500 add 1 wc for every 500 persons

For a population in excess of 1500 add 1 urinal for every 300 persons

For a population in excess of 1500 add 1 whb for every 500 persons

For a population in excess of 1500 add 1 wc for every 150 persons

For a population in excess of 1500 add 1 whb for every 500 persons

 

Facilities subject to off peak demand

50

1

0

1

1

1

100

1

1

1

2

1

150

1

2

1

3

2

250

2

3

2

5

3

500

2